Skip to content

Scanner fails to scan the artifacts... #587

@SupremeGab26

Description

@SupremeGab26

Current Behavior

When the artifacts was being scanned, the scanner just stays at the artifact tab and not hovering to different artifacts like it normally does when scanning others like weapons. It work

Expected Behavior

The scanner continues to scan

Reproducing a Behavior

20251003_185729.1.mp4

Device OS

Windows 11

Genshin Impact Version

6.0

Inventory Kamera Version

1.3.17

Screen resolution, screen mode, and UI scale

1440x900 Borderless

Additional notes and remarks

Error Log from within the scanner:

Index was out of range. Must be non-negative and less than the size of the collection.

Parameter name: index

at System.ThrowHelper.ThrowArgumentOutOfRangeException(ExceptionArgument argument, ExceptionResource resource)

at InventoryKamera.InventoryScraper.ProcessScreenshot(Bitmap screenshot, Double weight)

at InventoryKamera.InventoryScraper.GetPageOfItems(Int32 pageNum, Boolean acceptLess)

at InventoryKamera.ArtifactScraper.ScanArtifacts(Int32 count)

at InventoryKamera.InventoryKamera.GatherData()

P.S I found a similar error but it was already closed and not yet solved...

Evidence

2025-10-03 18:48:56.543|INFO|MainForm|Starting scan
2025-10-03 18:48:56.543|INFO|MainForm|Hotkey registered
2025-10-03 18:48:56.543|INFO|MainForm|Scan settings:
Game Version Data: 6.0
Weapons: False
Artifacts: True
Characters: False
Dev Items: False
Materials: False
Min Weapon Rarity: 3
Min Weapon Level: 1
Equip Weapons: True
Min Artifact Rarity: 5
Min Artifact Level: 20
Equip Artifacts: True
Delay: 2
2025-10-03 18:48:56.543|DEBUG|Navigation|Checking for GenshinImpact.exe
2025-10-03 18:48:56.553|DEBUG|Navigation|Found GenshinImpact.exe
2025-10-03 18:48:56.553|DEBUG|Navigation|Window location (1440x900): x=0, y=0
2025-10-03 18:48:56.594|INFO|InventoryKamera|Kamera initialized
2025-10-03 18:48:56.594|INFO|MainForm|Resolution: 1440x900
2025-10-03 18:48:56.604|INFO|InventoryKamera|Logging directory reset
2025-10-03 18:48:56.628|DEBUG|InventoryKamera|Thread #14 priority: Normal
2025-10-03 18:48:56.628|DEBUG|InventoryKamera|Added 2 workers
2025-10-03 18:48:56.628|DEBUG|InventoryKamera|Thread #12 priority: Normal
2025-10-03 18:48:57.272|DEBUG|GenshinProcesor|8 Engines restarted
2025-10-03 18:48:57.272|INFO|GenshinProcesor|Internally set traveler custom name to Yin
2025-10-03 18:48:57.272|INFO|GenshinProcesor|Internally set wanderer custom name to Fujin
2025-10-03 18:48:57.272|INFO|InventoryKamera|Scanning artifacts...
2025-10-03 18:49:07.682|WARN|InventoryScraper|Unable to locate full page of weapons with weight 0
2025-10-03 18:49:07.682|WARN|InventoryScraper|Detected 5 rows and 8 columns of items
2025-10-03 18:49:09.116|WARN|InventoryScraper|Unable to locate full page of weapons with weight -0.095
2025-10-03 18:49:09.116|WARN|InventoryScraper|Detected 5 rows and 6 columns of items
2025-10-03 18:49:10.553|WARN|InventoryScraper|Unable to locate full page of weapons with weight 0.03
2025-10-03 18:49:10.553|WARN|InventoryScraper|Detected 5 rows and 8 columns of items
2025-10-03 18:49:11.970|WARN|InventoryScraper|Unable to locate full page of weapons with weight -0.065
2025-10-03 18:49:11.970|WARN|InventoryScraper|Detected 5 rows and 7 columns of items
2025-10-03 18:49:13.498|ERROR|UserInterface|Index was out of range. Must be non-negative and less than the size of the collection.
Parameter name: index
at System.ThrowHelper.ThrowArgumentOutOfRangeException(ExceptionArgument argument, ExceptionResource resource)
at InventoryKamera.InventoryScraper.ProcessScreenshot(Bitmap screenshot, Double weight)
at InventoryKamera.InventoryScraper.GetPageOfItems(Int32 pageNum, Boolean acceptLess)
at InventoryKamera.ArtifactScraper.ScanArtifacts(Int32 count)
at InventoryKamera.InventoryKamera.GatherData()
2025-10-03 18:49:19.508|INFO|InventoryKamera|Done scanning artifacts
2025-10-03 18:49:19.618|DEBUG|InventoryKamera|Thread 12 exit
2025-10-03 18:49:19.868|DEBUG|InventoryKamera|Thread 14 exit
2025-10-03 18:49:19.868|INFO|MainForm|Data converted to GOOD
2025-10-03 18:49:19.868|INFO|MainForm|Exported data
2025-10-03 18:49:21.689|INFO|MainForm|Hotkey removed

Preflight Checklist

  • I have checked for similar issues in the issue page, and I have not found any similar to mine.
  • I am using the latest version of the scanner.
  • I tried setting the scanning delay to maximum, and it still doesn't work.
  • I have attached the video recording to the bug report.
  • I have attached the error log to the bug report.
  • I am available to later explains the issue.
  • I have disabled (or documented) all screen filtering software, plugins, and enhancements while scanning.
  • I use default in-game keybindings or have configured keybindings for the scanner.

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugSomething isn't working

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions