I was digging in a js source code at easee cloud and I found some reason for reason for no current and other things.
, g = {
0: "CHARGER_CONFIG_PROPERTIES.PGT_NOT_YET_DETECTED",
1: "CHARGER_CONFIG_PROPERTIES.PGT_TN_3_PHASE",
2: "CHARGER_CONFIG_PROPERTIES.PGT_TN_2_PHASE_PIN_2_3_4",
3: "CHARGER_CONFIG_PROPERTIES.PGT_TN_1_PHASE",
4: "CHARGER_CONFIG_PROPERTIES.PGT_IT_3_PHASE",
5: "CHARGER_CONFIG_PROPERTIES.PGT_IT_1_PHASE",
30: "CHARGER_CONFIG_PROPERTIES.PGT_WARNING_TN_2_PHASE_PIN_2_3_5",
31: "CHARGER_CONFIG_PROPERTIES.PGT_WARNING_TN_1_PHASE_NEUTRAL_ON_PIN_3",
50: "CHARGER_CONFIG_PROPERTIES.PGT_ERROR_NO_VALID_POWER_GRID_FOUND",
51: "CHARGER_CONFIG_PROPERTIES.PGT_ERROR_TN_400_V_NEUTRAL_ON_WRONG_PIN",
52: "CHARGER_CONFIG_PROPERTIES.PGT_ERROR_IT_GND_CONNECTED_TO_PIN_2_OR_3"
}
, f = {
0: "REASON_FOR_NO_CURRENT_SHORT.OK",
1: "REASON_FOR_NO_CURRENT_SHORT.PAUSED",
2: "REASON_FOR_NO_CURRENT_SHORT.PAUSED",
3: "REASON_FOR_NO_CURRENT_SHORT.PAUSED",
4: "REASON_FOR_NO_CURRENT_SHORT.PAUSED",
5: "REASON_FOR_NO_CURRENT_SHORT.PAUSED",
6: "REASON_FOR_NO_CURRENT_SHORT.PAUSED",
7: "",
8: "",
9: "REASON_FOR_NO_CURRENT_SHORT.ERROR_NO_CURRENT",
50: "",
51: "REASON_FOR_NO_CURRENT_SHORT.PAUSED",
52: "REASON_FOR_NO_CURRENT_SHORT.PAUSED",
53: "REASON_FOR_NO_CURRENT_SHORT.CHARGER_DISABLED",
54: "REASON_FOR_NO_CURRENT_SHORT.WAITING_AUTH",
55: "Pending authorization",
56: "REASON_FOR_NO_CURRENT_SHORT.ERROR_NO_CURRENT",
100: ""
I think this is status codes.:
Offline: 0,
Disconnected: 1,
AwaitingStart: 2,
Charging: 3,
Completed: 4,
Error: 5,
ReadyToCharge: 6
I was digging in a js source code at easee cloud and I found some reason for reason for no current and other things.