125 changes: 124 additions & 1 deletion zhaquirks/tuya/tuya_thermostat.py
Original file line number Diff line number Diff line change
Expand Up @@ -126,6 +126,16 @@ def __init__(self, *args, **kwargs):
)


class TuyaThermostatExtendedLimits(TuyaThermostat):
"""Tuya local thermostat cluster with extended temperature limits up to 45C."""

_CONSTANT_ATTRIBUTES = {
Thermostat.AttributeDefs.abs_min_heat_setpoint_limit.id: 500,
Thermostat.AttributeDefs.abs_max_heat_setpoint_limit.id: 4500,
Thermostat.AttributeDefs.ctrl_sequence_of_oper.id: Thermostat.ControlSequenceOfOperation.Heating_Only,
}


class NoManufTimeNoVersionRespTuyaMCUCluster(TuyaMCUCluster):
"""Tuya Manufacturer Cluster with set_time mod."""

Expand All @@ -140,7 +150,7 @@ class ServerCommandDefs(TuyaMCUCluster.ServerCommandDefs):

def handle_mcu_version_response(
self,
payload: TuyaMCUCluster.MCUVersion, # type:ignore[valid-type]
payload: TuyaMCUCluster.MCUVersion, # type: ignore[valid-type]
) -> foundation.Status:
"""Handle MCU version response."""
return foundation.Status.SUCCESS
Expand Down Expand Up @@ -606,3 +616,116 @@ def handle_mcu_version_response(
.skip_configuration()
.add_to_registry()
)


moes_base_quirk = (
TuyaQuirkBuilder()
.tuya_dp(
dp_id=1,
ep_attribute=TuyaThermostatExtendedLimits.ep_attribute,
attribute_name=TuyaThermostatExtendedLimits.AttributeDefs.system_mode.name,
converter=lambda x: {
True: Thermostat.SystemMode.Heat,
False: Thermostat.SystemMode.Off,
}[x],
dp_converter=lambda x: {
Thermostat.SystemMode.Heat: True,
Thermostat.SystemMode.Off: False,
}[x],
)
.tuya_switch(
dp_id=2,
attribute_name="manual_mode",
translation_key="manual_mode",
on_value=0,
off_value=1,
fallback_name="Manual mode",
)
.tuya_switch(
dp_id=3,
attribute_name="schedule_mode",
on_value=0,
off_value=1,
translation_key="schedule_mode",
fallback_name="Schedule mode",
)
.tuya_dp(
dp_id=36,
ep_attribute=TuyaThermostatExtendedLimits.ep_attribute,
attribute_name=TuyaThermostatExtendedLimits.AttributeDefs.running_state.name,
converter=lambda x: RunningState.Heat_State_On if not x else RunningState.Idle,
)
.tuya_switch(
dp_id=40,
attribute_name="child_lock",
translation_key="child_lock",
fallback_name="Child lock",
)
.tuya_enum(
dp_id=43,
attribute_name="temperature_sensor_select",
enum_class=SensorMode,
translation_key="sensor_mode",
fallback_name="Sensor mode",
)
.tuya_number(
dp_id=28,
attribute_name=TuyaThermostatExtendedLimits.AttributeDefs.local_temperature_calibration.name,
type=t.int32s,
min_value=-30,
max_value=30,
unit=UnitOfTemperature.CELSIUS,
step=0.1,
translation_key="local_temperature_calibration",
fallback_name="Local temperature calibration",
)
.adds(TuyaThermostatExtendedLimits)
.skip_configuration()
)

(
moes_base_quirk.clone()
.applies_to("_TZE204_aoclfnxz", "TS0601")
.applies_to("_TZE204_xalsoe3m", "TS0601")
.applies_to("_TZE204_u9bfwha0", "TS0601")
.applies_to("_TZE200_ztvwu4nk", "TS0601")
.tuya_dp(
dp_id=16,
ep_attribute=TuyaThermostatExtendedLimits.ep_attribute,
attribute_name=TuyaThermostatExtendedLimits.AttributeDefs.occupied_heating_setpoint.name,
converter=lambda x: x * 100,
dp_converter=lambda x: x // 100,
)
.tuya_dp(
dp_id=24,
ep_attribute=TuyaThermostatExtendedLimits.ep_attribute,
attribute_name=TuyaThermostatExtendedLimits.AttributeDefs.local_temperature.name,
converter=lambda x: x * 10,
)
.tuya_dp(
dp_id=18,
ep_attribute=TuyaThermostatExtendedLimits.ep_attribute,
attribute_name=TuyaThermostatExtendedLimits.AttributeDefs.max_heat_setpoint_limit.name,
converter=lambda x: x * 10,
dp_converter=lambda x: x // 10,
)
.tuya_number(
dp_id=20,
attribute_name="deadzone_temperature",
type=t.uint16_t,
unit=UnitOfTemperature.CELSIUS,
min_value=0,
max_value=5,
step=1,
translation_key="deadzone_temperature",
fallback_name="Deadzone temperature",
)
.tuya_dp(
dp_id=26,
ep_attribute=TuyaThermostatExtendedLimits.ep_attribute,
attribute_name=TuyaThermostatExtendedLimits.AttributeDefs.min_heat_setpoint_limit.name,
converter=lambda x: x * 10,
dp_converter=lambda x: x // 10,
)
.add_to_registry()
)